UJI CEMARAN BAKTERI COLIFORM PADA AIR MINUM ISI ULANG DARI DEPOT DI KELURAHAN TAROK DIPO BUKITTINGGI

  • Hilmarni Hilmarni Akademi Farmasi Imam Bonjol Bukittinggi Sumatera Barat
  • Zelia Ningsih Akademi Farmasi Imam Bonjol Bukittinggi Sumatera Barat
  • Riki Ranova Akademi Farmasi Imam Bonjol Bukittinggi Sumatera Barat
Keywords: coliform, MPN, refill water

Abstract

Test of Coliform contamination have been done into refill water at Kelurahan Tarok Dipo Bukittinggi. For safety, drinking water should have pathogen-free microbial conditions and harmful substances. The purpose of this study was to determine the contaminants of coliform bacteria and it is expected can provide information about the quality of refill water to the public. Test into Escherichia coli contamination was performed by Most Probable Number Test (MPN) method consisted of presumptive and confirmative testing. From eight samples examined showed that four positive samples of Coliform bacteria in presumptive testing, followed by confirmatory testing of four samples containing non-fecal Coliform bacteria. The results tests showed that 50% refill water of samples did not have the microbiology requirements.

References

Anonim, 2004, Keputusan Menteri Perindustrian dan Perdagangan No. 651 Tahun 2004 tentang Persyaratan Teknis Depot Air Minum dan Perdagangannya, Departemen Perindustrian dan Perdagangan RI, Jakarta.
Anonim, 2010, Peraturan Menteri Kesehatan Republik Indonesia nomor: 492/Menkes/Per/IV/2010, Departemen Kesehatan RI, Jakarta.
Bambang, A. G., Fatimawali, & Novel S. K., 2014, Analisis Cemaran Bakteri Coliform dan Identifikasi Escherichia Coli Pada Air Isi Ulang Dari Depot di Kota Manado, Jurnal Ilmiah Farmasi UNSRAT Vol 3 No 3, 325-334.
Cappucino, J.G and Sherman N., 2004, Microbiology; A Laboratory Manual, 7th edition, Benjamin Cumings.
Entjang, I. 2003. Mikrobiologi dan Parasitologi untuk Akademi Keperawatan dan Sekolah Tenaga Kesehatan yang Sederajat, Citra Adtya Bakti, Bandung.
Pratiwi S.T., 2008, Mikrobiologi Farmasi, Fakultas Farmasi, Universitas Gadjah Mada, Yogyakarta, Penerbit Erlangga.
Suriawiria. U, 2008, Mikrobiologi Air dan Dasar-dasar Pengolahan Buangan Secara Biologis, Alumni, Bandung.
Sutrisno C. T., & Suciastuti E., 2002, Teknologi Penyediaan Air Bersih, Rineka Cipta, Jakarta.
Waluyo Lud, 2007, Mikrobiologi Umum, UPT Penerbitan Universitas Muhammadiyah, Malang.
Wandrivel, R., Netty S., & Yuniar L., 2012, Kualitas Air Minum yang Diproduksi Depot Air Minum Isi Ulang di Kecamatan Bungus Padang Berdasarkan Persyaratan Mikrobiolgi, Jurnal FK Unand, 129-133.
Published
2018-08-04
How to Cite
Hilmarni, H., Ningsih, Z., & Ranova, R. (2018). UJI CEMARAN BAKTERI COLIFORM PADA AIR MINUM ISI ULANG DARI DEPOT DI KELURAHAN TAROK DIPO BUKITTINGGI. PROSIDING SEMINAR KESEHATAN PERINTIS, 1(1). Retrieved from https://jurnal.upertis.ac.id/index.php/PSKP/article/view/60